Skip to content
Molekula

Molekula

Nessler's Reagent

SKU 90033454 MW N/A In stock Bulk quantities on request

Supplying 4,500+ customers in over 80 countries

ISO 9001:2015 & ISO 14001:2015 certified · Supplying laboratories and industry since 2000 · Listed pack sizes are a starting point — we manufacture, source and repack to the quantity you need

Nessler’s Reagent is a chemical solution used primarily for detecting ammonia and ammonium ions in water and other samples through its formation of a yellow to brownish precipitate. Composed of mercury(II) iodide and potassium iodide in potassium hydroxide, it reacts with ammonia to produce a measurable color change. This reagent is classified as **Danger** due to its mercury content and requires careful handling. Molekula supplies Nessler’s Reagent from research to bulk quantities with full documentation and ISO 9001:2015 traceability.

Expect a response within hours Speak to a chemist: +44 (0) 3302 000333

Example image for illustration only. Other packaging and pack sizes are available.

Pricing & pack sizes

Pack sizes & pricing

These pack sizes aren't a limit. Molekula manufactures, sources and repacks to order — if you need 500 kg and only see 1 kg listed, . We quote from grams to multi-tonne.

Need a different size? Add the nearest pack and change the size in your basket — we price it at the same rate per unit.

  • 500 mL — £217.30 per pack ex VAT · £260.76 inc. VAT

Need a different quantity or pack?

Tell us how much you need and when — drums, IBCs, sacks or a one-off bulk lot. We'll manufacture or source it and come back with a price.

Quantity
Unit
Needed by
Full name
Email
Company
Phone (optional)
Notes

Expect a response within hours

Prices exclude VAT/sales tax and shipping.

Specifications

Property Value
Appearance Clear colourless to light yellow liquid
Boiling Point 104 - 106°C
Solubility in water miscible in water
Sensitivity to Ammonium Passes Test

Storage & handling

Property Value
Storage Temperature Ambient
Transport Class 8 (6.1)
Packing Group I
Acidity Neutral

Identification

Property Value
SKU 90033454
Molecular Weight N/A
UN Number UN2922
REACH Code Y110
HTS Code 3822.19.0080
Tariff Code 3822190090

Safety & GHS

Danger
  • GHS pictogram — Corrosive Corrosive GHS05
  • GHS pictogram — Toxic Toxic GHS06
  • GHS pictogram — Serious Health Hazard Serious Health Hazard GHS08
  • GHS pictogram — Hazardous to the Environment Hazardous to the Environment GHS09

Hazard statements

  • H290 May be corrosive to metals
  • H301 Toxic if swallowed
  • H310 Fatal in contact with skin
  • H314 (sub cat. 1A) Causes severe skin burns and eye damage
  • H330 Fatal if inhaled
  • H373 May cause damage to organs through prolonged or repeated exposure
  • H410 Very toxic to aquatic life with long lasting effects

Precautionary statements

  • P260 Do not breathe dust/fume/gas/mist/vapours/spray
  • P273 Avoid release to the environment
  • P280 Wear protective gloves/protective clothing/eye protection/face protection
  • P301+310 IF SWALLOWED: Immediately call a POISON CENTER or doctor/physician
  • P303+361 IF ON SKIN (or hair): Remove immediately all contaminated clothing. Rinse with water/shower
  • P304+312 IF INHALED: Call a POISON CENTER or doctor/physician if you feel unwell

Documents

Certificate of Analysis (CoA) by batch

Enter a lot or batch number to retrieve the CoA for that specific batch. We can generate one from spec data if no PDF is on file.

Synonyms

No alternate names recorded for this product.

Frequently asked questions

What is Nessler’s Reagent primarily used for?

Nessler’s Reagent is primarily used for the **colorimetric determination of ammonia and ammonium ions** in water and other samples, forming a yellow to brownish precipitate.

What is the chemical formula of Nessler’s Reagent?

The reagent is typically a **potassium tetraiodomercurate(II) solution** (K₂[HgI₄]) in potassium hydroxide (KOH), often prepared fresh due to instability.

How should Nessler’s Reagent be stored?

Store at **ambient temperature** in a tightly sealed container, away from light and moisture, and prepare fresh when possible for accurate results.

What grade of Nessler’s Reagent does Molekula supply?

Molekula supplies **analytical-grade Nessler’s Reagent** suitable for laboratory testing, ensuring compliance with standard analytical methods.

Can Molekula supply Nessler’s Reagent in bulk quantities?

Yes, bulk quantities are available upon request—contact our sales team for custom packaging and pricing for larger orders.

What documentation comes with an order of Nessler’s Reagent?

Each order includes a **Certificate of Analysis (CoA)**, Safety Data Sheet (SDS), and batch-specific documentation for traceability and compliance.

Ready to order or need a custom pack?

Tell us the product, grade, and quantity — Molekula usually responds within one working day with pricing and lead time.

Talk to a chemist
Documents Pricing
Request a quote
Tell us the product and the quantity you need — including quantities larger than our listed packs. Expect a response within hours.
Full name
Company
Email
Phone (optional)
Product
Quantity needed

Ask for whatever you actually need — the pack sizes on our catalogue pages are a starting point, not a limit.

Message
View basket